PRODUCT FEATURES   

Up to 11.1Gbps Data Links

Up to 10km transmission on SMF

DFB Laser and PIN receiver

Metal enclosure, for lower EMI

2-wire interface with integrated Digital Diagnostic monitoring

Hot-pluggable SFP+ footprint

Specifications compliant with SFF 8472

Compliant with SFP+ MSA with LC connector

Single 3.3V power supply

Case operating temperature range:0°C to 70°C  

Power dissipation < 1.5 W 

 APPLICATIONS

10GBASE-LR/LW & 10G Ethernet

STANDARD

Compliant to SFF-8431

Compliant to SFF 8472

RoHS Compliant.

 Absolute Maximum Ratings   

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Storage Temperature

Ts

-40

-

85

ºC


Relative Humidity

RH

5

-

95

%


Power Supply Voltage

VCC

-0.3

-

4

V


Signal Input Voltage


Vcc-0.3

-

Vcc+0.3

V


 Recommended Operating Conditions

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Case Operating Temperature

Tcase

0

-

70

ºC

Without air flow

Power Supply Voltage

VCC

3.14

3.3

3.47

V


Power Supply Current

ICC

-


450

mA


Data Rate

BR


10.3125


Gbps


Transmission Distance

TD


-

10

km


Coupled fiber

Single mode fiber

9/125um SMF

 Optical Characteristics 

Parameter

Symbol

Min

Typ

Max

Unit

NOTE

Transmitter







Output Opt. Power

POUT

-6


-0.5

dBm

1

Optical Wavelength

λ

1260

1310

1355

nm


Spectral Width (-20dB)

σ



1

nm


Optical Extinction Ratio

ER

3.5



dB


Output Eye Mask

Compliant with IEEE 802.3ae


Receiver







Rx Sensitivity

RSENS



-14.4

dBm

2

Input Saturation Power (Overload)

Psat

0.5



dBm


Wavelength Range

λC

1270


1610

nm


LOS De -Assert

LOSD



-17

dBm


LOS Assert

LOSA

-30



dBm


LOS Hysteresis


0.5

1.0


dB


Notes:   

1. Class 1 Laser Safety per FDA/CDRH and IEC-825-1 regulations.   

2. Measured with a PRBS 231-1 test pattern, @10.325Gb/s, BER<10-12 .  

IV. Electrical Characteristics 

Parameter

Symbol

Min

Typ

Max

Unit

NOTE

Supply Voltage

Vcc

3.14

3.3

3.46

V


Supply Current

Icc



450

mA


Transmitter







Input differential impedance

Rin


100


Ω

1

Single ended data input swing

Vin,pp

180


700

mV


Transmit Disable Voltage

VD

Vcc–1.3


Vcc

V


Transmit Enable Voltage

VEN

Vee


Vee+ 0.8

V

2

Transmit Disable Assert Time




10

us


Receiver







Differential data output swing

Vout,pp

300


850

mV

3

Data output rise time

tr

28



ps

4

Data output fall time

tf

28



ps

4

LOS Fault

VLOS fault

Vcc–1.3


VccHOST

V

5

LOS Normal

VLOS norm

Vee


Vee+0.8

V

5

Power Supply Rejection

PSR

100



mVpp

6

Notes:  

1. Connected directly to TX data input pins. AC coupled thereafter.   

2. Or open circuit.   

3. Into 100 ohms differential termination.   

4. 20 – 80 %.

5. Loss Of Signal is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.   

6. Receiver sensitivity is compliant with power supply sinusoidal modulation of 20 Hz to 1.5 MHz up to specified value applied through the recommended power supply filtering network.   

 

 

 

 

 

 

 

 

V. Pin Assignment

 

 Pin out of Connector Block on Host Board

Pin

Symbol

Name/Description

NOTE

1

VEET

Transmitter Ground  (Common with Receiver Ground)

1

2

TFAULT

Transmitter Fault.

2

3

TDIS

Transmitter Disable. Laser output disabled on high or open.

3

4

SDA

2-wire Serial Interface Data Line

4

5

SCL

2-wire Serial Interface Clock Line

4

6

MOD_ABS

Module Absent. Grounded within the module

4

7

RS0

Rate Select 0

5

8

LOS

Loss of Signal indication.  Logic 0 indicates normal operation.

6

9

RS1

No connection required

1

10

VEER

Receiver Ground  (Common with Transmitter Ground)

1

11

VEER

Receiver Ground  (Common with Transmitter Ground)

1

12

RD-

Receiver Inverted DATA out.  AC Coupled


13

RD+

Receiver Non-inverted DATA out.  AC Coupled


14

VEER

Receiver Ground  (Common with Transmitter Ground)

1

15

VCCR

Receiver Power Supply


16

VCCT

Transmitter Power Supply


17

VEET

Transmitter Ground  (Common with Receiver Ground)

1

18

TD+

Transmitter Non-Inverted DATA in. AC Coupled.


19

TD-

Transmitter Inverted DATA in.  AC Coupled.


20

VEET

Transmitter Ground  (Common with Receiver Ground)

1

Notes:

1. Circuit ground is internally isolated from chassis ground.

2. TFAULT is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on the host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V.A high output indicates a transmitter fault caused by either the TX bias current or the TX output power exceeding the preset alarm threshold. A low output indicates normal operation. In the low state, the output is pulled to <0.8V.

3. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.

4. Should be pulled up with 4.7kΩ- 10kΩ host board to a voltage between 2.0V and 3.6V. MOD_ABS pulls line low to indicate module is plugged in. 

5. Internally pulled down per SFF-8431 Rev 4.1. 

6. LOS is open collector output. It should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.

 

VI. Digital Diagnostic Functions

SFPP-1396-10BD   transceivers support the 2-wire serial communication protocol as defined in the SFP+ MSA.

The standard SFP serial ID provides access to identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information.

 

Additionally, SFP+ transceivers provide a unique enhanced digital diagnostic monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage. It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range.

 

The SFP MSA defines a 256-byte memory map in EEPROM that is accessible over a 2-wire serial interface at the 8 bit address 1010000X (A0h).The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally defined serial ID memory map remains unchanged.

 

The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the SFP transceiver into those segments of the E2PROM that are not write-protected. The negative edge clocks data from the SFP transceiver.  The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Transceiver Interface Block Diagram



 

 

 

 

VII. Outline Dimensions

Comply to SFF-8432 rev. 5.0, the improved Pluggable form factor specification.

 

VIII. Regulatory Compliance 

Feature

Reference

Performance

Electrostatic dischargeESD

IEC/EN 61000-4-2

Compatible with standards

Electromagnetic Interference (EMI)

FCC Part 15 Class B EN 55022 Class B (CISPR 22A)

Compatible with standards

Laser Eye Safety

FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Class 1 laser product

ROHS

2002/95/EC

Compatible with standards

EMC

EN61000-3

Compatible with standards

Appendix A. Document Revision

Version No.

Date

Description

1.0

2010-09-01

Preliminary datasheet

2.0

2011-09-10

Update format and company’s logo

 


SFPP-1396-10BD 10Gb/s 1310nm SFP+ 10km Transceiver

SFPP-1396-10BD 10Gb/s 1310nm SFP+ 10km Transceiver

扫描二维码分享到微信